Multi Parameter Monitor – PM12F
12.1 inch Touch screen
Parameter:

ECG,SPo2,PR,NIBP,TEMP,RESP.

Optional:

1.Recorder (Printer); 2.Central monitoring system; 3.Single/double IBP; 4.ETCO2; 5.Masimo/Nellcor SPO2; 6.Sun Tech NIBP.

Warranty::

1 year

PRODUCT DETAILS

PM-12F fetal monitor can provide real-time fetal heart rate, fetal movement and uterine contraction data, which can help doctors keep abreast of the condition of the fetus and take appropriate measures to protect the health of the fetus

微信图片_20250309132710.png

1. light and compact design, simple to use front panel controls

2.12.1″ TFT Colour screen ,folding 90 degree

3. The system setup can be done very easy and can be stored automatically

4. The internal line 152mm thermal printer can records FHR ,TOCO ,The life exceed over 20 years

5.A standard patient event marker and a clinical event marking button to separately mark Clinical events

6.Auto Fetal movement are available

7. Multi-crystals ,wide beam form, high sensitivity ultrasound transducer ,low ultrasound power, Safer to the fetal

8. AC or LI-battery operated

9. More than 12 hours data storage, then can be played and reprinted

10. Build-in interface to the central nurse station

11. Standerd parameters: TOCO,FHR,FM, Option: twins montiroing, FAS(Fetal acoustic simulator)

微信图片_20250309132721.png

  • Item Technical Specifications

  • FHR Transducer Multi-crystals, wide wave beam, pulsed-wave working method, high sensitivity

  • Strength < 5mW/cm2

  • Working Frequency 1.0MHz

  • Signal Processing Special DSP system and modern recognition

  • Measurement Range 50~240bpm

  • Alarm Range High Limit: 160, 170, 180, 190 bpm

  • Low Limit: 90, 100, 110, 120 bpm

  • Maximum Audio Output Power 1.5 Watt

  • TOCO Measurement Range 0-100 units

  • Display LCD shows The FHR trace, TOCO tracd, FM, Doctor Event Mark, Time, Volume etc monitor state, and also it can store and playback.

  • Environment Working Environmen Temperature: +5℃ ~ +40℃

  • Atmospheric Pressure 86kPa ~ 106kPa

  • Transport and Storage Temperature Humidity: < 93%

  • Atmospheric Pressure: 86kPa ~ 106kPa

  • Transducer Acoustic Output The peak negative acoustic pressure Does not exceed 1Mpa

  • The output beam intensity Does not exceed 20mW/cm2

  • The sound intensity Will not exceed 5mW/cm2

  • Spatial-peak temporal average intensity Does not exceed 100 mW/cm2

  • Other GEL Viscous aqueous non-sensitizing, hypo-allergenic and non-irritating to skin. Bacteriostat (not sterile)

  • Exterior Dimension 350L×320W×85H(mm)

  • Net Weight 3.5 kg