High-strength engineering plastic rack, light, beautiful and corrosion resistant
Adult, Child
O2: 0.05~1.0L/min,1.1~10L/min N2O: 0.05~1.0L/min,1.1~10L/min Air: 0.1~10L/min
MJ-560B5 Anesthesia Machine, with its ergonomic design, integrated structure, easy for transport. The microcomputer-controlled Ventilator adopts imported sensors and other components Its scientific and proper design as well as rigorous production process. Comprehensive monitoring and alarm, high-precision vaporizer, three gas source inputs, sensitive flow control system, highly integrated breathing circuit, with multiple modern technologies applied, the Anesthesia Machine is both outstanding it performance and versatile in functions.
COMPREHENSIVE MONITORING & INTELLIGENT SYSTEM
Large screen high-definition 10.4 " TFT wide-angle color LCD Touch Screen display
Extra-large workbench with larger capacity drawers
Comprehensive wavefor information display
Timely alarm function an selfcheck function to avoid various risks caused by surgery
Intelligent anesthesia information management system
PRECISION CONTROL SYSTEM
Supports input of 3 gas sources: Oxygen, Nitrous oxide and Air
Equipped with 5 tubes high-precision flow meters, to ensure precise regulation of Oxygen, Nitrous oxide, and Air
O2-N2O Linkage and N2O Stopper, to ensure the minimum oxygen concentration and automatic protection of N2O safety
HIGH-PRECISION VAPORIZER
Vaporizer can support low flow anesthesia as low as 0.2L/min and large flow anesthesia up to 15L/min.
Accurate output of concentrations under varying conditions of pressure, flow and temperature.
4 Kinds of Vaporizer for Choice: Halothane, Enflurane, Isoflurane and Sevoflurane
Fill-in type: Pouring
INTEGRATED BREATHING CIRCUIT
Integrated breathing circuit with APL valve, excellent tightness and safety.
Made of special materials, resistant to corrosion and high temperature.
Compact structure, no external pipelines, good mechanical compliance.
Impeller sampling is used at the exhalation end to avoid inaccurate monitoring of tidal volume due to water vapor condensation.
Drive bellows is not required to repalce when operating pediatric anesthesia.
Large volume of CO2 canister, single tank structure for more convenient in assembly.
TECHNICAL PARAMETERS
PART OF ANESTHESIA MACHINE
■Main Body
High-strength engineering plastic rack, light, beautiful and corrosion resistant
■Scope of Application:
Adult, Child
■Gas Source
O2: 0.28~0.6MPa, N2O: 0.28~0.6MPa, Air
■Flow Meter
O2: 0.05~1.0L/min,1.1~10L/min
N2O: 0.05~1.0L/min,1.1~10L/min
Air: 0.1~10L/min
■O2-N2O Linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.16±0.02Kpa, the flow of nitrous oxide would be cut off.
■Flow Rate of Rapid Oxygen Supply
25~75L/min
■Low Oxygen Pressure Alarm
There will be sound alarm when the oxygen pressure < 0.2MPa
■Vaporizer
It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Among Halothane,Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer.
■Respiratory Circuit
Working mode: All-close, Semi-close, Semi-open
APL: ≤12.5 kPa
■Respiratory Bellows
Bellows for adults and children
Tidal volume range: 0~1500 ml
PART OF VENTILATOR
■Display Mode
High-definition 10.4”TFT color LCD touch screen display, easy and convenient operation
■Ventilation Mode
VCV、PCV、SIMV、MANUAL
■Ventilation Function
PEEP,SIGH, IRV, Inspiratory platform, Standby
■Ventilation Parameters
Tidal volume:20~1500 ml
Rate:2~120 bpm
SIMV rate:2~20 bpm
I:E:4:1~1:8
Inspiratory trigger pressure: -10~20 cmH₂O
PEEP:0~25 cmH₂O
Pressure range:5~60 cmH₂O
SIGH:1.5 times the inspiratory time/ 60~120 times breath
Inspiratory platform: 0~50%
Pressure control:3~60 cmH₂O
Pressure slope:1~10 gear
■Parameters For Ventilation Monitoring
VI tidal volume, VE tidal volume, Minute Ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous breathing rate, I/E, peak pressure of airway, average pressure, PEEP, Inspiratory trigger pressure, inspiratory platform, oxygen concentration, battery capacity , pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure –volume loop
■Security Alarm System
Oxygen Concentration Alarm: Upper limit setting range:21%~99%,Low limit setting range:15%~80%
Airway Pressure Alarm: Upper limit setting range:5~60 cmH2O,Low limit setting range:0~1250pxH₂O
Per-minute Ventilation Volume Alarm: Upper limit setting range:1~30L/min, Low limit setting range: 0~29L/min
Tidal Volume alarm: Upper limit setting range:100~2000ml,Low limit setting range 0~1800ml
Sustained High Pressure Alarm: It will give alarm when stress have consistently been higher than 25 cmH2O for 15s.
Suffocation Alarm: It will give alarm when stress have consistently been higher than 10 cmH2O and tidal volume is less than 120ml for 15s.
Tube Escape Alarm: It will give alarm when stress have consistently been less than 50pxH2O for 15s.
Low Battery Level Alarm: It will give alarm when battery level is less than 14±0.5V
■Power Supply
AC 100~240V,50/60Hz
Built-in Li Battery (Work at least for 6-8 hours with battery)
■ Options
Mechanical Arms Bracket for Patient Monitor
ETCO2 monitoring