Search for more information

Menu

Anaesthesia Machine MJ-560B5
10.4 " TFT wide-angle color LCD Touch Screen display
Main Body:

High-strength engineering plastic rack, light, beautiful and corrosion resistant

Scope of Application::

Adult, Child

Flow Meter:

O2: 0.05~1.0L/min,1.1~10L/min N2O: 0.05~1.0L/min,1.1~10L/min Air: 0.1~10L/min

PRODUCT DETAILS

MJ-560B5 Anesthesia Machine, with its ergonomic design, integrated structure, easy for transport. The microcomputer-controlled Ventilator adopts imported sensors and other components Its scientific and proper design as well as rigorous production process. Comprehensive monitoring and alarm, high-precision vaporizer, three gas source inputs, sensitive flow control system, highly integrated breathing circuit, with multiple modern technologies applied, the Anesthesia Machine is both outstanding it performance and versatile in functions.

 

5.png

COMPREHENSIVE MONITORING & INTELLIGENT SYSTEM

Large screen high-definition 10.4 " TFT wide-angle color LCD Touch Screen display

Extra-large workbench with larger capacity drawers

Comprehensive wavefor information display

Timely alarm function an selfcheck function to avoid various risks caused by surgery

Intelligent anesthesia information management system


PRECISION CONTROL SYSTEM

Supports input of 3 gas sources: Oxygen, Nitrous oxide and Air

Equipped with 5 tubes high-precision flow meters, to ensure precise regulation of Oxygen, Nitrous oxide, and Air

O2-N2O Linkage and N2O Stopper, to ensure the minimum oxygen concentration and automatic protection of N2O safety


HIGH-PRECISION VAPORIZER

Vaporizer can support low flow anesthesia as low as 0.2L/min and large flow anesthesia up to 15L/min.

Accurate output of concentrations under varying conditions of pressure, flow and temperature.

4 Kinds of Vaporizer for Choice: Halothane, Enflurane, Isoflurane and Sevoflurane

Fill-in type: Pouring

 

INTEGRATED BREATHING CIRCUIT

Integrated breathing circuit with APL valve, excellent tightness and safety.

Made of special materials, resistant to corrosion and high temperature.

Compact structure, no external pipelines, good mechanical compliance.

Impeller sampling is used at the exhalation end to avoid inaccurate monitoring of tidal volume due to water vapor condensation.

Drive bellows is not required to repalce when operating pediatric anesthesia.

Large volume of CO2 canister, single tank structure for more convenient in assembly.

 

TECHNICAL PARAMETERS

PART OF ANESTHESIA MACHINE

■Main Body                

High-strength engineering plastic rack, light, beautiful and corrosion resistant

 

■Scope of Application:

Adult, Child

 

■Gas Source                

O2: 0.28~0.6MPa, N2O: 0.28~0.6MPa, Air

 

■Flow Meter                

O2: 0.05~1.0L/min,1.1~10L/min

N2O: 0.05~1.0L/min,1.1~10L/min

Air: 0.1~10L/min

 

■O2-N2O Linkage and N2O Stopper

When using nitrous oxide, oxygen concentration>25%;

When the oxygen pressure<0.16±0.02Kpa, the flow of nitrous oxide would be cut off.

 

■Flow Rate of Rapid Oxygen Supply   

25~75L/min


 ■Low Oxygen Pressure Alarm    

There will be sound alarm when the oxygen pressure < 0.2MPa


■Vaporizer

It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%.

Among Halothane,Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer.

 

■Respiratory Circuit           

Working mode: All-close, Semi-close, Semi-open

APL: ≤12.5 kPa

 

■Respiratory Bellows          

Bellows for adults and children

Tidal volume range: 0~1500 ml

 

PART OF VENTILATOR

■Display Mode              

High-definition 10.4”TFT color LCD touch screen display, easy and convenient operation


 ■Ventilation Mode          

VCV、PCV、SIMV、MANUAL


■Ventilation Function         

PEEP,SIGH, IRV, Inspiratory platform, Standby

 

■Ventilation Parameters        

Tidal volume:20~1500 ml

Rate:2~120 bpm

SIMV rate:2~20 bpm

I:E:4:1~1:8

Inspiratory trigger pressure: -10~20 cmH₂O

PEEP:0~25 cmH₂O

Pressure range:5~60 cmH₂O

SIGH:1.5 times the inspiratory time/ 60~120 times breath

Inspiratory platform: 0~50%

Pressure control:3~60 cmH₂O

Pressure slope:1~10 gear

 

■Parameters For Ventilation Monitoring

VI tidal volume, VE tidal volume, Minute Ventilation volume, IPPV rate, SIMV rate,  total respiratory rate, autonomous breathing rate, I/E, peak pressure of airway, average pressure, PEEP, Inspiratory trigger pressure, inspiratory platform, oxygen concentration, battery capacity , pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure –volume loop

 

■Security Alarm System

Oxygen Concentration Alarm: Upper limit setting range:21%~99%,Low limit setting range:15%~80%

Airway Pressure Alarm: Upper limit setting range:5~60 cmH2O,Low limit setting range:0~1250pxH₂O

Per-minute Ventilation Volume Alarm: Upper limit setting range:1~30L/min, Low limit setting range: 0~29L/min

Tidal Volume alarm: Upper limit setting range:100~2000ml,Low limit setting range   0~1800ml

Sustained High Pressure Alarm: It will give alarm when stress have consistently been higher than 25 cmH2O for 15s.

Suffocation Alarm: It will give alarm when stress have consistently been higher than  10 cmH2O and tidal volume is less than 120ml for 15s.

Tube Escape Alarm: It will give alarm when stress have consistently been less than 50pxH2O for 15s.

Low Battery Level Alarm: It will give alarm when battery level is less than 14±0.5V

 

■Power Supply

AC 100~240V,50/60Hz

Built-in Li Battery (Work at least for 6-8 hours with battery)

 

■ Options

Mechanical Arms Bracket for Patient Monitor

ETCO2 monitoring