High sensitivity, reliability, and reproducibility of results due to ECL technology Up to 18 assays can be run at a throughput of up to 86 tests/h 9 min STAT applications for emergency sample assays (incl. TnT Gen. 5, Creatine-Kinase MB, Myoglobin, Parathyroid Hormone (PTH), and human Chorionic Gonadotropin (hCG)1
cobas e 411 disk analyzer cobas e 411 rack analyzer Optional System Table (cabinet); Optional System Table Extension (for printer)
Disk: 180 kg / 397 lbs Rack: 250 kg / 551 lbs
Roche Cobas e411 Chemistry Analyzer Cobas e 411 analyzer is fully automated, uses patented electrochemiluminescence, and combines the reliability of Roche/Hitachi systems with the analytical excellence of electrochemiluminescence, creating an excellent immunoassay system.
Description
cobas e 411 analyzer is fully automated and uses patented electrochemiluminescence (ECL) technology to perform immunoassay analyses. It has been developed for various applications for quantitative and qualitative in vitro assays (including anemia markers and bone, cardiac and tumor markers, critical care, fertility/hormones, pregnancy care, and infectious diseases). The analyzer is available as a rack system or disk system.
The Cobas e 411 combines the reliability of Roche/Hitachi systems with the analytical excellence of electrochemiluminescence, creating an excellent immunoassay system. By providing 18 simultaneous immunology parameters 24/24 hours, the Cobas e 411 offers high availability and response times of 9 to 27 minutes. Multifaceted, it both automates immunoassays in small and medium-sized laboratories and serves to perform specialties in larger laboratories.
The extensive test menu sets the Cobas e 411 apart. Roche’s Clinical Chemistry and Immunology test menu, the most extensive on the market, allows you to run routine and special parameters on the same analytical platform. The laboratory can thus provide differentiated and routine tests simultaneously and in good time, with maximum analytical quality.
Roche Cobas e411 Chemistry Analyzer Features:
High sensitivity, reliability, and reproducibility of results due to ECL technology
Up to 18 assays can be run at a throughput of up to 86 tests/h
9 min STAT applications for emergency sample assays (incl. TnT Gen. 5, Creatine-Kinase MB, Myoglobin, Parathyroid Hormone (PTH), and human Chorionic Gonadotropin (hCG)1
Carryover-free pipetting of samples to avoid cross-contamination
Automated sample rerun capability
Continuous random access and flexible STAT priority settings
The use of disposable tips for all sample pipetting delivers carryover free pipetting to avoid cross-contamination
Economic usage with high stabilities and convenient kit sizes
High uptime of 98.6%
Low system maintenance time
Fully automatic immunological analyzer with up to 88 t / h.
It needs the shortest time to obtain the final result of all immunological analyzers – between 9 and 18 minutes. This is because the measurement method is ECL, which also allows a wider measurement range and greater sensitivity and needs smaller quantities of serum.
Possibility of continuous addition of samples at any moment of the process.
Possibility of setting urgent samples under STAT.
The unique concept of programming is just by inserting the reagents, calibrators, controls, and serums into the instrument and its launch. At the start, the instrument detects the barcode and starts working. This option increases efficiency in the laboratory.
A wide range of tests of over 75 covers the 7 different areas of indication. It is desirable to note that, unlike some instruments, there is no need for any selectivity through indication areas by defining the tests.
The reagents do not need any preparation (Ready To Use); they are on the drive with temperature control.
During the work at each pipetting, the reagents open and close automatically, so they are protected from external influences in every moment of the process.
This possibility to automatically open and close the reagents and temperature control increases the durability of the reagents inserted on the instrument to 60 days, even for the most sensitive tests.
Great stability of calibration of the lot has changed significantly reduced costs.
In the reliability of the results in every moment of the process, despite the increased stability of reagents and calibrations, also contributes to the detection level and opening coagulum (Clot Detection).
The possibility of transmission and contamination of the sample is reduced by using special pipettors for one use only at any pipetting of serum or reagent. This is another fact that increases the reliability of the results.
Ability to work with serum, plasma, and urine.
System software is perfected and standardized with all Cobas platforms. Performance of the PC – is significantly improved compared to the Elecsys 2010. Here are the biggest changes made in respect of Elecsys 2010 to simplify the system for the user.
Benefits
Easy to Operate
Innovative technology
STAT facilities for urgent sample
Unique programming-by-loading concept
Assay menu
Thyroid Function
Fertility / Hormones
Anemia
Tumor Markers
Cardiac
Maternal Care
Critical Care
Infectious Disease
Bone Markers
Three ways to achieve unmatched performance
As the heart of the Cobas e 411 analyzers, ECL technology delivers the unique combination of nine-minute STAT applications, high analytical sensitivity, and wide measuring ranges for unparalleled performance in immunochemistry.
Wide measuring ranges reduce the amount of tests rerun due to out-of-range results
Examples:
-Estradiol range of 5 – 4,300 pg/mL
-Progesterone range of 0 – 60 ng/mL
-total-PSA range of 0 – 100 ng/mL
High analytical sensitivity enables the use of innovative tests and requires less sample volume examples:
-Troponin T 4th gen. with <10% cv at 95th population percentile
-hCG+‚ and TSH requires 10 and 50 μL sample volume, respectively
Nine minutes STAT applications deliver unmatched turnaround time for emergency samples
-hCG+ß, Troponin T 4th Gen., CK-MB, Myoglobin, PTH*
Include:
ANTIMULLERIAN HORMONE (AMH) Reagent for Roche Elecsys 2010 / Cobas E411
TROPONIN THS Elecsys Reagent for Roche Elecsys 2010 / Cobas E411
PRECICONTROL AMH for Roche Elecsys 2010 / Cobas E411
PAPP-A Elecsys Reagent for Roche Elecsys 2010 / Cobas E411
CALCITONIN Reagent for Roche Elecsys 2010 / Cobas E411
N-MID OSTEOCALSIN Elecsys Reagent for Roche Elecsys 2010 / Cobas E411
VITAMIN D TOTAL II Reagent for Roche Elecsys 2010 / Cobas E411 – 100 Test
CALSET CALSITONIN for Roche Elecsys 2010 / Cobas E411
FREE HCG beta Elecsys Reagent for Roche Elecsys 2010 / Cobas E411
ANTI-HCV II Elecsys Reagent for Roche Elecsys 2010 / Cobas E411
ANTI-HAV GEN.2 Elecsys Reagent for Roche Elecsys 2010 / Cobas E411
ROCHE COBAS E411 IMMUNOLOGY SAMPLE RACK SET