Leica DMi8 Automated Inverted Microscope DMi8 M/S/A
Live Cell Research,Advanced Widefield Research,Enhanced Viewing,Speed and Efficiency,Precise Control
Microscope Type:Inverted, Automated:

Viewing Head:Trinocular:

Focus Mechanism:Motorized Z-focus:

PRODUCT DETAILS

Discover the precision of the Leica DMi8 Inverted Microscope for your live cell research. Offering unparalleled imaging capabilities, increased viewing areas, and fast acquisition speeds, the Leica DMi8 is the researcher’s choice for advanced microscopy. Elevate your scientific investigations with the DMi8 today.


Description

The Leica DMi8 Inverted microscope takes you beyond configuration restrictions. With the freedom of a completely modular system, you can create the perfect system for your needs. With the Leica DMi8, you only buy what you need.

If your application would benefit from autofocus or 3D images, you can integrate a motorized focus drive into an otherwise manual system. Or if you need to image in multiple colors, start with a motorized filter wheel and manual focus. With hundreds of possible combinations, you can create the best-customized solution for your work.


The Leica DMi8 microscope is a versatile and advanced imaging platform designed for various scientific fields, particularly live cell research. It is a modular, inverted microscope system that is part of the DMi8 S platform solution, providing a complete set of tools for routine to complex live cell experiments. It can track the development of single cells, screen through multiple assays, and achieve single molecule resolution.


The DMi8 is known for its increased viewing area, rapid image acquisition, and precise control, essential for in-depth biological research and analysis. With options for customization and expansion, the DMi8 system can cater to a wide range of microscopy needs, from basic observation to high-end research applications.

微信图片_20250401185513.png

The Leica DMi8 Inverted Microscope allows for:

1、Live Cell Research: It provides a complete solution for tracking the development of cells over time, screening through assays, achieving single molecule resolution, and observing complex cellular processes1.

2、Advanced Widefield Research: It can high-speed control and advanced imaging with features like Infinity TIRF and software capabilities that support in-depth live cell imaging studies1.

3、Enhanced Viewing: With the ability to increase the viewing area up to 10,000 times, the microscope’s software module, LAS X Navigator, allows researchers to obtain a comprehensive overview of samples and set up high-resolution image acquisition automatically1.

4、Speed and Efficiency: Experiments can be conducted up to five times faster due to the LAS X Synapse advanced sequencer, which coordinates system components for rapid imaging and precise control of the system with micro-second precision1.

5、Precise Control: It offers the ability to add additional devices for specialized applications and high-speed experiments, allowing for detailed analysis of an organism’s response to stimuli, which is essential in dynamic live cell experiments1.


A fully automated widefield system for fluorescence and brightfield imaging.

The DMi8 is a fully automated widefield system for fluorescence and brightfield imaging. It has a full range of objectives, monochrome and color cameras, and filter sets to enable fluorescence imaging of up to four distinct channels from UV to far red excitation.


DMi8 for advanced widefield research

Starting from the discovery and analysis of single molecules and culminating in breakthroughs in understanding and treating human health, the key to the next scientific discovery lies in finding the missing links connecting your data.


The DMi8 S is a flexible solution for advanced widefield research. The new DMi8 S platform extends the flexibility of the DMi8 microscope, adding high-speed control, Infinity TIRF, plus advanced software capabilities to create the solution for your advanced live cell imaging.


Product Specs

During testing, this Leica DMi8 Microscope was found to have no issues. A clear image was produced through the eyepieces and the camera port. The mechanical and motorized components moved freely, and the test sample could be focused without excessive effort.

微信图片_20250401185417.png

The system consists of:

  1. Base:

  2. Leica DMi8 Inverted Microscope

  3. CTRadvanced Control Box / Power Supply

  4. Head:

  5. Binocular Tube

  6. (2) HC PLAN s 10x/22 M Eyepieces

  7. Condenser / Prisms:

  8. 7-position Motorized S28 0.55 Condenser

  9. Brightfield Path:

  10. Tiltable Transmitted Illumination Arm

  11. Fluorescence Light Path:

  12. Base

  13. Light Guide and Collimating Adapter

  14. Fluorescence Filter Cubes:

  15. 6-position Motorized Filter Cube Turret

  16. Texas red (custom) EX:548/25, DM:620, EM:600/60

  17. CFP (custom) EX:438/15, DM:458/105, EM:480/30

  18. GFP (custom) EX:473/35, DM:530, EM:538/45

  19. *Other filters available – please inquire*

  20. Illumination Type:

  21. TL-LED 12V 15W LED Lamp w/ control/power box

  22. Lumencor Spectra 7 Light Engine w/ light guide and collimating adapter

  23. Stage Type:

  24. Motorized XY Stage

  25. MCX-2 eco Controller w/ Joystick

  26. Objectives:

  27. 6-position Motorized Objective turret

  28. 5x/0.15 HCX PL FLUOTAR (O03795)

  29. 10x/0.32 HC PL FLUOTAR (O03788)

  30. 40x/0.75 HCX PL FLUOTAR (O03749)

  31. *Other objectives available – please inquire*

  32. Photo / Port Splits:

  33. 100% Eyepiece or 100% Camera Port

  34. Camera:

  35. 10MP CMOS Camera

  36. Motorized Components:

  37. Condenser, Fluorescence turret, Objective turret, Z-axis, XY stage, Lightpath switching, Shutters

  38. Computer and Software:

  39. Computer running camera software, MicroManager software, and Leica LAS X software


Communication and power cables

Configuration and Setup:

Orientation: Inverted

Illumination Type: Brightfield, Fluorescence

Objectives: 5x/0.15 HCX PL FLUOTAR, 10x/0.32 HC PL FLUOTAR, 40x/0.75 HCX PL FLUOTAR

Light Sources: 12V LED Lamp, Lumencor Spectra 7

Stage: Motorized XY