Product Discription
Features
1.Digital signal processor for effective inhibition of baseline drift, AC interference filter, MG interference filter and the heart rate, to guarantee the authenticity and dependability
2.Auto-regulation of baseline drift can effectively inhibit baseline drift, optimizing the printing position to achieve high-quality ECG
3.Have regular automatically measuring and analyzing function for ECG parameters to lessen doctor's load.
4.With a high -resolution thermal printer to print out ECG trace, describing the trace clear and accurate, annotation as well as related parameters for diagnostic reference.
5.Roll recording paper for ECG is 80mm in width, simultaneous 12 lead acquisitions and 3 lead live record, high affectivity of ECG examination, good effect and economic utility.
6.Function of rhythm lead for observing abnormal ECG trace & heart rate.
7.Supported by AC/Rechargeable battery for continuous examination whenever necessary. For Battery operation.
8.ECG is equipped with a battery charger and a system for battery capacity management and protection
Safety level for ECG corresponds to Type CF, Class I according to the IC60601-1 criterion. The amplifier is floating input circuit which can examine human cordis directly with safety and reliability
Items specification
Lead standard 12 leads
lead acquisition synchronously 12 leads
Input circuit Floating; Protection circuit against Defibrillator effect
Input Impedance ≥50MΩ
Input circuit current ≤0.0.05 A
Record mode Automatic: 3CH×4+1R, 3CH×4,
3СН×2+2CH×3,3CH×2+2CH×3+1R,6CHX2;
Manual: 3CH, 2CH, 3CH+1R, 2CH+1R;
Rhythm: Any lead selectable.
Filter EMG Filter: 25 Hz / 30 Hz/ 40H2/75 Hz/ 100 Hz / 150Hz
DFT Filter: 0.05 Hz/ 0.15 Hz
AC Filter: 50 Hz/ 60Hz
CMRR >100dB
Patient current leakage <10 A
Input Circuit Current <0.05 A
Frequency Response 0.05Hz~150Hz (-3dB)
Sensitivity 2.5mm/m V, 5 mm/m V, 10 mm/m V, 20 mm/mV
Anti-baseline Drift Automatic
Time constant ≥3.2s
Noise level <15 Vpp
Paper speed 12.5 mm/s, 25 mm/s, 50 mm/s
Recording mode Thermal printing system
Paper specification 80mmx20m paper roll
LCD display 7''graphic LCD
Safety classification IEC60601-1 class I, type CF
Power supply AC: 100~240V, 50/60Hz, 30VA~100VA
DC: 14.8V/2200mAh, built-in lithium battery
Fuse AC220V=10% 2*Ф5×20mm, T2A/250V AC time lag
AC110V+10% 2*Ф5×20mm.T4A/250V AC time lag