21 μL
41x50x43cm 25Kg
50 tubes (up to 10 racks, 5 tubes per rack)
CELL-DYN Emerald 22 AL Hematology Analyzer
Simply smart
With reduced budgets, shrinking laboratory space and staffing challenges, many laboratories need a solution that lets them work smarter with less.
The CELL-DYN Emerald 22 AL is a full performance, automated optical 5-part differential analyzer that delivers smarter results for small to mid-size clinical laboratories.
Compact design
Conserve valuable laboratory space with a small footprint and only 2 reagents, plus onboard cleaner
Walkaway functionality
Optimize hematology workflow with 50 tube load-up capacity.
Ease of use
Reduce hands-on time with touch-free scheduled daily maintenance, startup and shutdown
Decrease manual entry errors and help to comply by use of barcoded reagents
Smart safety features
Ensure user safety with a specially developed open tube sample device
Prevent errors with optional tube bypass for specimens with unreadable barcodes
System Specifications
Technology & Methods | Optical Flow Cytometry technology Electrical impedance Absorption spectrophotometry Electronic valves Cyanide-free lyse reagent LCD color touch screen RS232 and TCP/IP LIS interface Multiple USB ports (3 in front, 1 in back) |
Throughput | 40 samples per hour |
Autoloader Capacity | 50 tubes (up to 10 racks, 5 tubes per rack) |
Sample Size | 21 μL |
Specimen Data Management | Search by date or sequence number Flagging for patient limit sets Flagging for panic values 3,000 records with histograms on internal memory Up to 300,000 records on external USB thumb drive Customizable patient limits and report units (USA, SI, SI MOD) Barcode reader (reads code 128, code 39, interleaved 2 of 5, and others listed in the Operator’s Manual) |
Quality Control | 12 control files 100 records per file Levey-Jennings graphs Upload/download control information eQC online peer review program |
Demographics | Sequence number Alphanumeric specimen ID Date & time analyzed Patient name CBC with or without 5-part differential Flagging and Alerts |
Dispersional Data Alert | Operator-defined patient limits for low, high, ad panic values System-defined limits for reportable range and analytical measurement range Suspect parameter flags caused by interfering substances or sample abnormalities Suspect parameter flags generated when WBC data indicates possible presence of an abnormal population |
Standards & Safety Compliance | CAN/CSA-C22.2 No. 61010-1 IEC 61010-1 IEC 61010-2-101 IEC 61326-1 IEC 61326-2-6 IEC 60825-1 CE Mark |
Physical Dimensions | Height - 16.1 inches (41 cm) Width - 19.7 inches (50 cm) Depth - 17.0 inches (43 cm) Weight - approximately 55 lbs. (25 kg) (without on-board reagents) |