Search for more information

Menu

2000B3 ICU Ventilator Machine
10.4” LCD color screen display various measuring
Ventilation Mode:

VCV,PCV,SIMV,PSV,PSV SIMV,CPAP

size/weight::

68X68X136 cm 62Kg

Material:

metal, Plastic, Steel, Resin AC 100~240V,50/60Hz

PRODUCT DETAILS

2000B3 Ventilator is a multi-functional Ventilator adopting pneumatic, electronic control and microcomputer technology. Imported components guarantee operational stability and reliability. With 10.4” LCD color screen display various measuring and configuration parameters, the device is very suitable for respiratory treatment, applicable for first aid department, surgical department, gynecological departments, pediatrics department, and ICU department of hospitals. Built-in Air Compressor, the machine can be used directly in the ICU department.

ddcafa867be95e99f0c2f17f9936ff8.png

TECHNICAL PARAMETERS

■Display Mode              

High-definition 10.4”TFT color LCD display, easy and convenient operation

 

■Ventilation Mode          

VCV,PCV,SIMV,PSV,PSV SIMV,CPAP


■Ventilation Function         

PEEP,SIGH,Standby,IP,IRV

 

■Ventilation Parameters        

Tidal volume:20~2000ml

Rate:2~120bpm

SIMV rate:2~20bpm

I:E:4:1~1:8

Inspiratory trigger pressure:-10~20 cmH2O

Flow trigger sensitivity:1-20L/min

PEEP:0~25 cmH2O

Pressure control:3~60 cmH2O

Pressure limit:5~60 cmH2O

Pressure slope:1~10 gear

Flow rate setting:1~10 gear

Expiratory trigger sensitivity:10%~90%

Time control:1~10s

SIGH:1.5 times the inspiratory time(60-120 times adjustable)

Inspiratory platform:0~50%

Oxygen concentration:21%~99%


■Parameters for Ventilation Monitoring

VI tidal volume, VE tidal volume, Minute Ventilation volume, IPPV rate, SIMV rate, Total respiratory rate, autonomous breathing rate, I/E, peak pressure of airway, average pressure, PEEP, Inspiratory trigger pressure, inspiratory platform, oxygen concentration, battery capacity, pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure –volume loop

 

■Security Alarm System

Oxygen Concentration Alarm: Upper limit setting range:21%~99%,Low limit setting range:15%~80%

Airway Pressure Alarm: Upper limit setting range:1~60 cmH2O,Low limit setting range:0~50cmH₂O

Per-minute Ventilation Volume Alarm: Upper limit setting range:1~30L/min, Low limit setting range: 0~20L/min

Tidal Volume alarm: Upper limit setting range:10~2000ml,Low limit setting range   0~1800ml

Respiratory rate:Upper limit setting range 10~99bPm;Low limit setting range 0~50 bPm

Sustained High Pressure Alarm: It will give alarm when stress have consistently been higher than 25 cmH2O for 15s.

Low Battery Level Alarm: It will give alarm when battery level is less than 14±0.5V

Gas shortage alarm

Low pressure of Oxygen alarm

Low pressure of Air alarm

Power alarm                    

Intubation off alarm

 

■Air compressor with Standby function

 

■Power Supply

AC 100~240V,50/60Hz

Built-in Li Battery (Work at least for 4-6 hours with battery)