VCV,PCV,SIMV,PSV,PSV SIMV,CPAP
PEEP,SIGH,Standby,IP,IRV
1 year
2000B2 Ventilator is a multi-functional Ventilator adopting pneumatic, electronic control and microcomputer technology. Imported components guarantee operational stability and reliability. With 10.4” LCD color screen display various measuring and configuration parameters, the device is very suitable for respiratory treatment, applicable for first aid department, surgical department, gynecological departments, pediatrics department, and ICU department of hospitals. Air source port on the machine need to be connected if use in the ICU department.
■Display Mode
High-definition 10.4”TFT color LCD display, easy and convenient operation
■Ventilation Mode
VCV,PCV,SIMV,PSV,PSV SIMV,CPAP
■Ventilation Function
PEEP,SIGH,Standby,IP,IRV
■Ventilation Parameters
Tidal volume:20~2000ml
Rate:2~120bpm
SIMV rate:2~20bpm
I:E:4:1~1:8
Inspiratory trigger pressure:-10~20 cmH2O
Flow trigger sensitivity:1-20L/min
PEEP:0~25 cmH2O
Pressure control:3~60 cmH2O
Pressure limit:5~60 cmH2O
Pressure slope:1~10 gear
Flow rate setting:1~10 gear
Expiratory trigger sensitivity:10%~90%
Time control:1~10s
SIGH:1.5 times the inspiratory time(60-120 times adjustable)
Inspiratory platform:0~50%
Oxygen concentration:21%~99%
■Parameters For Ventilation Monitoring
VI tidal volume, VE tidal volume, Minute Ventilation volume, IPPV rate, SIMV rate, total respiratory rate, autonomous breathing rate, I/E, peak pressure of airway, average pressure, PEEP, Inspiratory trigger pressure, inspiratory platform, oxygen concentration, battery capacity , pressure - time waveform, flow rate - time waveform, flow-volume loop, pressure –volume loop
■Security Alarm System
Oxygen Concentration Alarm: Upper limit setting range:21%~99%,Low limit setting range:15%~80%
Airway Pressure Alarm: Upper limit setting range:1~60 cmH2O,Low limit setting range:0~50cmH₂O
Per-minute Ventilation Volume Alarm: Upper limit setting range:1~30L/min, Low limit setting range: 0~20L/min
Tidal Volume alarm: Upper limit setting range:10~2000ml,Low limit setting range 0~1800ml
Respiratory rate:Upper limit setting range 10~99bPm;Low limit setting range 0~50 bPm
Sustained High Pressure Alarm: It will give alarm when stress have consistently been higher than 25 cmH2O for 15s.
Low Battery Level Alarm: It will give alarm when battery level is less than 14±0.5V
Gas shortage alarm
Low pressure of Oxygen alarm
Low pressure of Air alarm
Power alarm
Intubation off alarm
Battery voltage alarm
■Power Supply
AC 100~240V,50/60Hz
Built-in Li Battery (Work at least for 4-6 hours with battery)