Search for more information

Menu

NEW Hamilton T1 Transport ICU Specs Ventilator
The ability to ventilate Adult / paediatric and Neonatal patients,
Description:

Approvals and certificates for use in ambulances, helicopters and airplanes Adult, pediatric, and neonatal (w/neomode option) ventilation Independence from compressed air Up to 9 hours of battery operating time Noninvasive ventilation and integrated high flow oxygen therapy* Advanced ventilation modes, including ASV® Digital solutions for respiratory care: Hamilton Connect Module & App

Warranty:

1-Year

offers:

Approvals and certificates for use in ambulances, helicopters and airplanes Adult, pediatric, and neonatal ventilation (w/neomode option) Independence from gas cylinders or compressors More than 9 hours of battery operating time Noninvasive ventilation and integrated high flow oxygen therapy Advanced ventilation modes, including ASV® – Adaptive Support Ventilation

PRODUCT DETAILS

#Hamilton T1 Transport Ventilator : Product description This ventlator is an advanced turbine-based ICU and transport ventilator designed to deliver precise and reliable respiratorysupport for adut, pediatric, and neonatal patients. With intelligent ventilation modes, integrated turbine technology, andcomprehensive monitoring, it ensures consistent performance across ICU, emergency, and transport environments.


Application Area

Intensive Care Units (ICU)

Emergency and Trauma Departments

Operation Theatres

Inter-hospital and intra-hospital transport

Ambulances and air transport

 Neonatal and Pediatric ICUs


Key Features:

Integrated turbine air supply (no central compressed air required)

 Supports adult, pediatric, and neonatal patients

 Advanced volume- and pressure-controlled ventilation modes

 Intelligent Adaptive Support Ventilation (ASV)

Non-invasive ventilation (NIV) and High-Flow Oxygen Therapy

High-resolution color TFT display with waveforms and loops

Comprehensive alarm system with priority levels

 Internal lithium-ion battery for transport use

Suitable for ICU, emergency, and inter-hospital transport


Hospital Benefits:

Ensures ventilation continuity during patient transport

Reduces dependence on central compressed air systems 

One ventilator for multiple patient categories

Enhances patient safety through advanced alarms and monitoring

Optimized for both critical care and mobility

微信图片_20250326172652.png

The HAMILTON-T1 offers:

  1. Approvals and certificates for use in ambulances, helicopters and airplanes

  2. Adult, pediatric, and neonatal ventilation (w/neomode option)

  3. Independence from gas cylinders or compressors

  4. More than 9 hours of battery operating time

  5. Noninvasive ventilation and integrated high flow oxygen therapy

  6. Advanced ventilation modes, including ASV® – Adaptive Support Ventilation


The intelligent solution for the mobile ICU

The HAMILTON-T1 is designed to ventilate the Adult / Paediatric and Neonatal ICU patient at any place around the world. With its compact size of less than 6.5 kg, built in batteries with up to 8 hours operating time, 8.4” color touch screen and its high performance turbine, this ICU ventilator can accompany your patient within the hospital and between hospitals, whether on the ground or in the air. Its integrated high performing NIV capabilities add state-of-the-art therapy options for any transport situation.



The HAMILTON-T1 delivers a cost-effective ICU ventilation solution that is appropriate for all patients – from paediatric to adult. In mobile ICU ambulances, in helicopters, in long distance ambulance jets, in intra-hospital transport, in emergency departments, and in the ICU, the HAMILTON-T1’s fast setup and easy management ensure the most appropriate treatment for every patient.


The HAMILTON-T1 is specifically designed to cover the needs of rescue personnel, health care teams, and their patients. It is the ideal choice for air ambulance teams as it can ventilate all patients, can run from any power source (AC or DC), is independent from compressed gas, and is approved for the flight environment. The HAMILTON-T1 offers a choice of sturdy mounting solutions to fit a broad variety of needs. The HAMILTON-T1 integrates solutions for mechanical mounts, worldwide electrical supplies, multiple gas supplies and on airway CO2 monitoring.


Hamilton Connect Module

The Hamilton Connect Module integrated in the ventilator provides the HAMILTON-C1/T1 with the capability of secure wireless communication with patient data management systems, monitoring systems, and the Hamilton Connect App.


Hamilton Connect App

Hamilton Connect App connects your mobile device to your Hamilton Medical ventilator and allows you to access selected ventilation data.

微信图片_20250326173500.png

Features

In addition to its unique features, the HAMILTON-T1 includes everything you expect from a high-performance ICU transport ventilator:

A choice of ventilation modes for invasive and optionally non-invasive ventilation

Individualized, lung-protective ventilation with INTELLiVENT®-ASV®

An extensive monitoring package

CPR ventilation

Upgraded high flow oxygen therapy

Volume Support mode

Digital solutions for respiratory care: Hamilton Connect Module and App

Remote access to HAMILTON-H900 controls and status

The ability to ventilate Adult / paediatric and Neonatal patients,

Hot swappable batteries

Automatic compensation of changes in barometric pressures

IPX4 protection against heavy rain


Technical Specifications

Ventilation Modes: APCVomy / S(C)MV+, APVsimv/ SIMV+, PCV+, PSIMV+, DuoPAP, APRV, SPONT, ASV, NIV, NIV-ST,nCPAP, HiFlow O2

Tidal Volume Range: Adult/Pediatric: 20-2000 ml, Neonatal: 2-300 ml

Inspiratory Pressure: 0-60 cmH2O

Maximum Inspiratory Flow: 260 L/min (120 L/min at 100% O2)

Trigger Mechanism: Flow trigger control

 Oxygen Mixing Accuracy: +(2.5% + 2.5% of actual reading)

Air Supply: Integrated turbine

High-Pressure Oxygen Input: 2.8-6 bar

Low-Pressure Oxygen Input: Maximum 6 bar

Patient Connection Ports: ISO ID 15/OD 22 conical

Input Power: 100-240 VAC +10%, 50/60 Hz | 12-28 VDC

Power Consumption: 50 VA typical, 150 VA maximum

Battery Type: Lithium-ion

 Battery Backup: One battery: approx. 4-4.5 hours, Two batteries: up to 8-9 hours

Screen: Color TFT display

Display Type: High-resolution graphical interface

Waveforms: Pressure, Volume, Flow, PCO2, FCO2

 Loops: Pressure-Volume, Pressure-Flow, Volume-Flow

Trends: 1, 6, 12, 24, 72 hours


Content in the box

· Ventilator main unit

· Patient breathing circuit

· Power cable and DC adapter

· Oxygen hose

· User manual

·Battery


FAQ

Is this ventilator turbine-based or compressor-based?

This ventilator is turbine-based and does not require central compressed air.

Can it be used for neonatal patients?

Yes, it supports neonatal ventilation with low tidal volume settings.

Is it suitable for patient transport?

Yes, it is designed for ICU and transport use with internal battery backup.

Does it support non-invasive ventilation?

Yes, NIV, NIV-ST, and High-Flow Oxygen Therapy are supported.

Can it operate without an oxygen cylinder?

Yes, it operates on room air using the turbine; oxygen is optional.