Approvals and certificates for use in ambulances, helicopters and airplanes Adult, pediatric, and neonatal (w/neomode option) ventilation Independence from compressed air Up to 9 hours of battery operating time Noninvasive ventilation and integrated high flow oxygen therapy* Advanced ventilation modes, including ASV® Digital solutions for respiratory care: Hamilton Connect Module & App
1-Year
Approvals and certificates for use in ambulances, helicopters and airplanes Adult, pediatric, and neonatal ventilation (w/neomode option) Independence from gas cylinders or compressors More than 9 hours of battery operating time Noninvasive ventilation and integrated high flow oxygen therapy Advanced ventilation modes, including ASV® – Adaptive Support Ventilation
#Hamilton T1 Transport Ventilator : Product description This ventlator is an advanced turbine-based ICU and transport ventilator designed to deliver precise and reliable respiratorysupport for adut, pediatric, and neonatal patients. With intelligent ventilation modes, integrated turbine technology, andcomprehensive monitoring, it ensures consistent performance across ICU, emergency, and transport environments.
Application Area
Intensive Care Units (ICU)
Emergency and Trauma Departments
Operation Theatres
Inter-hospital and intra-hospital transport
Ambulances and air transport
Neonatal and Pediatric ICUs
Key Features:
Integrated turbine air supply (no central compressed air required)
Supports adult, pediatric, and neonatal patients
Advanced volume- and pressure-controlled ventilation modes
Intelligent Adaptive Support Ventilation (ASV)
Non-invasive ventilation (NIV) and High-Flow Oxygen Therapy
High-resolution color TFT display with waveforms and loops
Comprehensive alarm system with priority levels
Internal lithium-ion battery for transport use
Suitable for ICU, emergency, and inter-hospital transport
Hospital Benefits:
Ensures ventilation continuity during patient transport
Reduces dependence on central compressed air systems
One ventilator for multiple patient categories
Enhances patient safety through advanced alarms and monitoring
Optimized for both critical care and mobility

The HAMILTON-T1 offers:
Approvals and certificates for use in ambulances, helicopters and airplanes
Adult, pediatric, and neonatal ventilation (w/neomode option)
Independence from gas cylinders or compressors
More than 9 hours of battery operating time
Noninvasive ventilation and integrated high flow oxygen therapy
Advanced ventilation modes, including ASV® – Adaptive Support Ventilation
The intelligent solution for the mobile ICU
The HAMILTON-T1 is designed to ventilate the Adult / Paediatric and Neonatal ICU patient at any place around the world. With its compact size of less than 6.5 kg, built in batteries with up to 8 hours operating time, 8.4” color touch screen and its high performance turbine, this ICU ventilator can accompany your patient within the hospital and between hospitals, whether on the ground or in the air. Its integrated high performing NIV capabilities add state-of-the-art therapy options for any transport situation.
The HAMILTON-T1 delivers a cost-effective ICU ventilation solution that is appropriate for all patients – from paediatric to adult. In mobile ICU ambulances, in helicopters, in long distance ambulance jets, in intra-hospital transport, in emergency departments, and in the ICU, the HAMILTON-T1’s fast setup and easy management ensure the most appropriate treatment for every patient.
The HAMILTON-T1 is specifically designed to cover the needs of rescue personnel, health care teams, and their patients. It is the ideal choice for air ambulance teams as it can ventilate all patients, can run from any power source (AC or DC), is independent from compressed gas, and is approved for the flight environment. The HAMILTON-T1 offers a choice of sturdy mounting solutions to fit a broad variety of needs. The HAMILTON-T1 integrates solutions for mechanical mounts, worldwide electrical supplies, multiple gas supplies and on airway CO2 monitoring.
Hamilton Connect Module
The Hamilton Connect Module integrated in the ventilator provides the HAMILTON-C1/T1 with the capability of secure wireless communication with patient data management systems, monitoring systems, and the Hamilton Connect App.
Hamilton Connect App
Hamilton Connect App connects your mobile device to your Hamilton Medical ventilator and allows you to access selected ventilation data.

Features
In addition to its unique features, the HAMILTON-T1 includes everything you expect from a high-performance ICU transport ventilator:
A choice of ventilation modes for invasive and optionally non-invasive ventilation
Individualized, lung-protective ventilation with INTELLiVENT®-ASV®
An extensive monitoring package
CPR ventilation
Upgraded high flow oxygen therapy
Volume Support mode
Digital solutions for respiratory care: Hamilton Connect Module and App
Remote access to HAMILTON-H900 controls and status
The ability to ventilate Adult / paediatric and Neonatal patients,
Hot swappable batteries
Automatic compensation of changes in barometric pressures
IPX4 protection against heavy rain
Technical Specifications
Ventilation Modes: APCVomy / S(C)MV+, APVsimv/ SIMV+, PCV+, PSIMV+, DuoPAP, APRV, SPONT, ASV, NIV, NIV-ST,nCPAP, HiFlow O2
Tidal Volume Range: Adult/Pediatric: 20-2000 ml, Neonatal: 2-300 ml
Inspiratory Pressure: 0-60 cmH2O
Maximum Inspiratory Flow: 260 L/min (120 L/min at 100% O2)
Trigger Mechanism: Flow trigger control
Oxygen Mixing Accuracy: +(2.5% + 2.5% of actual reading)
Air Supply: Integrated turbine
High-Pressure Oxygen Input: 2.8-6 bar
Low-Pressure Oxygen Input: Maximum 6 bar
Patient Connection Ports: ISO ID 15/OD 22 conical
Input Power: 100-240 VAC +10%, 50/60 Hz | 12-28 VDC
Power Consumption: 50 VA typical, 150 VA maximum
Battery Type: Lithium-ion
Battery Backup: One battery: approx. 4-4.5 hours, Two batteries: up to 8-9 hours
Screen: Color TFT display
Display Type: High-resolution graphical interface
Waveforms: Pressure, Volume, Flow, PCO2, FCO2
Loops: Pressure-Volume, Pressure-Flow, Volume-Flow
Trends: 1, 6, 12, 24, 72 hours
Content in the box
· Ventilator main unit
· Patient breathing circuit
· Power cable and DC adapter
· Oxygen hose
· User manual
·Battery
FAQ
Is this ventilator turbine-based or compressor-based?
This ventilator is turbine-based and does not require central compressed air.
Can it be used for neonatal patients?
Yes, it supports neonatal ventilation with low tidal volume settings.
Is it suitable for patient transport?
Yes, it is designed for ICU and transport use with internal battery backup.
Does it support non-invasive ventilation?
Yes, NIV, NIV-ST, and High-Flow Oxygen Therapy are supported.
Can it operate without an oxygen cylinder?
Yes, it operates on room air using the turbine; oxygen is optional.