COMEN NV10 High Frequency Neonatal Infant Ventilator
Neonatal/Pediatric Ventilator
Introduction:

HFNC + ROX – ROX index to optimize ventilation strategy. nCPAP + Apnea Auto-relief – Preset compulsory pressure-controlled ventilation after apnea detected DuoVent – Increase mean airway pressure (MAP) while maintain free breath. 2 Sync SNIPPV + Back Up Vent – Selectable synchronization methods to catch the breath at all times. NIPPV – Sustained alveolar ventilation during episodes of apnea Single-limb nHFO – Patented diaphragm ocssilator with single-limb ventilation to create a safety net for NIV

Ventilation Modes:

NCPAP, Duo Vent, NIPPV, SNIPPV, NHFO, HFNC

Size / Dimension:

373 x 264 x 287 mm 14KG

PRODUCT DETAILS

NV10 Neonatal Ventilator

Increase NIV Confidence Further than Ever


COMEN NV10 includes a complete NIV set with specialized ventilation tools for neonates and children, expanding the ventilation strategies to protect each spontaneous breath. It offers a robust ventilation system and elevates oxygenation level at all stages.


HFNC + ROX – ROX index to optimize ventilation strategy.

nCPAP + Apnea Auto-relief – Preset compulsory pressure-controlled ventilation after apnea detected

DuoVent – Increase mean airway pressure (MAP) while maintain free breath.

2 Sync SNIPPV + Back Up Vent – Selectable synchronization methods to catch the breath at all times.

NIPPV – Sustained alveolar ventilation during episodes of apnea

Single-limb nHFO – Patented diaphragm ocssilator with single-limb ventilation to create a safety net for NIV

微信图片_20250326210525.png

Oscillation Therapy Revolution


Multiple Benefits of nHFO Raise Profile in Clinical Research and Practice

The advantages of non-invasive high-frequency oscillation encompass enhanced carbon dioxide elimination, reduced dead space during ventilation, and effective treatment of persistent pulmonary hypertension (PPHN) when used with nitric oxide. There is a growing amount of academic research focusing on the benefits of non-invasive high frequency ventilation in new-born.


Minimization of Work of Breath in Every Detail

A single-limb setup, as opposed to a dual-limb configuration with a Y-piece and doubled tubing cavity, effectively reduces dead space, thereby decreasing the work of breathing of patients.


Unique Oscillator Design

The generation mechanisms on the market today are diaphragm oscillation piston type, bi-directional jet and high frequency flow-interrupter with expiration assist. NV10 adopts the most recognized method, diaphragm oscillation, and applied Comen’s unique and advance design which provide a quieter and more powerful oscillator, Covering all the scenario in practice.


Sensitively Respond to Patients Every Breath


2 Sync Modes with Unique Algorithm

The abdominal sensor is designed for quick response and cost-effectiveness. The pressure sensor minimizes false activations due


Apnea management

Data indicates that preterm infants with a gestational age of less than 29 weeks have an asphyxia risk nearing 100%. Both nCPAP and SNIPPV modes employ dual methods with a variety of parameters to closely monitor a patient’s respiratory condition, ensuring timely detection of any signs of apnea from all monitored parameters.


Targeted Pressure as Needed

Leakage Compensation System

The NV 10 is equipped with a leakage compensation system up to 100% pressure compensatory, ensuring that patients receive the set pressure in the event of leakage.