Fast sample quantification in 3 seconds with the adjustable pathlength selector.
190 - 1000 nm
@EzDrop 1000C Micro-Volume / Cuvette Spectrophotomete, EzDrop 1000C Micro-Volume/Cuvette Spectrophotometer helps you make the most of your precious sample and time, providing measurement results within 3 seconds. The instrument offers dual modes for micro-volume and cuvette detection, as well as an intuitive touch screen for easy operation. These features combine to meet a wide range of nucleic acid and protein quantification requirements. EzDrop 1000C can be used as a standalone unit or connected to a PC for increased flexibility in the sample-to-data process.
Dual Measurement Modes
Micro-Volume Mode
- Only 1 μL of undiluted sample is needed.
- The sample window is coated with a nano hydrophobic layer to stabilize the liquid column.
- The detection arm is cushioned to protect it from shock and impact during closure.
Cuvette Mode
- EzDrop 1000C has built in 37- 45°C temperature control and stir functions to meet specific applications.
Intuitive Touch Screen for Easy Operations
Operation of the 7 touchscreen is intuitive and allows the analysis of different samples with the touch of a button.
Assist Light for Perfect Placing of the Sample
The assist light minimizes sample placement errors caused by inadequate ambient lighting.
Flexible Data Management
EzDrop 1000C can be conveniently used as a standalone device, or connected to a computer for the easy generation of reports.
Spectrophotometer for Cuvette and Microvolumes
Independent system with clear touchpad
Multiple automated measurement functions allow you to quickly measure nucleic acids, proteins, cells, and other samples at the touch of a button.
Sophisticated design: an additional light source compensates for the lack of ambient light and minimizes errors in sample placement
(LED Assist Light).
A special nano-hydrophobic layer on the sample window ensures the formation of a stable sample column.
The sample glass can be completely replaced, significantly reducing the possibility of residual contamination
CV absorbance value is <1%.
The special design of the detection arm reduces pressure, which in turn reduces the error rate in experiments.
Data exchange: USB connection (csv-file)
Application Areas
Nucleic acid and protein analysis
OD600 measurement
Analysis of microarrays and labeled proteins
KineticsFull spectrum scans
General Technical Data EzDrop 1000C
Display | 7” touch screen, 1280*800 high-definition color display |
Connectivity | USB-A port x1 (Data output, csv-file); USB-B port x1 (PC connection) |
dimensions(W x D x H) | 206 x 333 x 166 mm |
Weight | 3.3 kg (7.3 lbs.) |
Glove suitability | Suitable for all laboratory gloves |
Internal storage | 32 GB flash memory |
Operating voltage | Input: AC 100-240 V, 50/60 Hz; Output: DC 24 V, 2.08 A |
Specifications EzDrop 1000C
Minimum sample volume | 1 µl |
Sample number | 1 |
Pathlength | 0.5 mm / 0.05 mm |
Light source | Pulsed xenon flash lamp |
Detector type | 2048 element CMOS |
Wavelength range | 190 - 1000 nm |
Wavelength accuracy | 1.0 nm |
Spectral resolution | 1.5 nm (FWHM bei Hg 253.7nm) |
Absorbance precision | Raw: 0.0015 A (0.5 mm); 0.03 A (1 cm equivalent) |
Absorbance accuracy | 1.5 % bei 1.0 A and 320 nm |
Absorptionsbereich (entspricht 1 cm) | 0.04 - 400 A |
Detection range | dsDNA: 2 – 20000 ng/µl BSA: 0.06 – 600 mg/mL |
Measurement time | < 3 sec. |
Cuvette Mode | |
Pathlength | 10, 5, 2, 1, 0.5, 0.2, 0.125, 0.1 mm |
Absorbance range (1 cm equivalent) | 0.002 - 1.5 A |
Detection range | dsDNA: 0.3 - 75 ng/µl; BSA: 0.003 - 2.25 mg/ml |
Stirring | 8 speeds 150 – 850 rpm |
Temperature control | 37 - 45°C ±0.5°C (Quartz Cuvette) |
Software (integrated) |
Operating system | Custom Linux based OS |
PC software requirements | Windows® 7 und 10, 64 bit |