Search for more information

Menu

ICU Ventilator AV-2000B2 8.4" TFT color LCD screen display
Ippv, Sippv, Simv, Peep, Manual, Sigh
Ventilation mode:

IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH

Display mode High-definition:

8.4" TFT color LCD screen display

Warranty:

2 years

PRODUCT DETAILS



AV-2000B2 Multi-functional Electric Hospital Vertical ICU Ventilator AV-2000B2 Multi-functional Electric Hospital Vertical ICU Ventilator


AV-2000B2 is a multi-functional Ventilator, adopting pneumatic, electronic control and microcomputer technology. Imported components are utilized to guarantee stablility and reliabiligyt. With color screen(TEF) to display various measuringand configuration parameters, the ventilator suitable for respiratory treatment, applicable for medical,surgical and gynecological department, pediatrics department, first aid, ICU etc.Air source cen be conneted.


Product Introduction:


AV-2000B2 is a multi-functional Ventilator, adopting pneumatic, electronic control and microcomputer technology. Imported components are utilized to guarantee stablility and reliabiligyt. With color screen(TEF) to display various measuringand configuration parameters, the ventilator suitable for respiratory treatment, applicable for medical,surgical and gynecological department, pediatrics department, first aid, ICU etc.Air source cen be conneted.


Ventilator:


Display mode

High-definition 8.4” TFT color LCD screen display

Ventilation  mode

IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH

Ventilation parameters

Tidal volume :       50~1500 ml

Rate :              2~99 bpm

SIMV rate :         2~20 bpm

I:E :               2:1~1:8

Inspiratory trigger pressure: -1.0~2.0kPa

PEEP:              0~2.0 kPa

Pressure range :      1.0~6.0 kPa

SIGH :    1.5 times the inspiratory time

Inspiratory platform :  0~50%

Parameters for ventilation monitoringtidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform
Monitoring of oxygen concentration21%~100%


Safety alarm system



Oxygen Concentration alarm

upper limit setting range 50%~100%

low limit setting range   15%~50%

Airway pressure alarmupper limit setting range   1.0~6.0 kPa

low limit setting range    0.4~2.0 kPa

Per-minute ventilation volume alarm

upper limit setting range 3.0~30L/min

low limit setting range  1.0~10L/min

Sustained high-pressure alarmit will give alarm when stress have consistently

been higher than 2.5 kPa

Suffocation alarmit will give sound and light alarm if there is no tidal volume input for 15 seconds
Power 

AC 220V±10%     50Hz±1Hz

 UPS, Storage battery